WMV650A Veterinary Patient Monitor
8 inch high resolution display for easy reading
Lightweight,portable design and user-friendly interface for easy operation
PRODUCT DETAILS
Features
8 inch high resolution display for easy reading
Lightweight,portable design and user-friendly interface for easy operation
Flexible configurations to meet different clinical needs
Built-in rechargeable Lithium-ion battery for fluid
Built-in rechargeable battery
5 hours continuous working
12 months warranty
SPECIFICATIONS
Display
8” color TFT LCD Screen,resolution: 600 x 800
NIBP
Measurement method : Automatic oscillometric method
Operating mode:Manual, automatic, continuous Measurement unit: mmHg/kPa selectable
Typical measurement time: 20~40s Measurement type: Systolic, Diastolic,Mean Measurement range (mmHg)
Range of Systolic pressure: Dog 40-270
Cat 40-200
Others 40-135
Range of Diastolic pressure: Dog 10-210
Cat 10-150
Others 10-95
Range of Mean pressure: Dog 20-230
Cat 20-165
Others 20-105
Measurement accuracy
Maximum average error: ±5mmHg
Maximum standard deviation: 8mmHg
Resolution: 1mmHg
Interval:1,2,3,4,5,10,15,30,60,90,120,180,240,480minutes Overpressure protection: Software and hardware,double
safety protection Cuff pressure range: 0-280mmHg
ECG
Lead type 3-lead:I, II, III
5-lead:I, II, III,aVR, aVL, aVF, V
Display sensitivity: 2.5mm/mV (×0.25), 5mm/mV (×0.5), 10mm/mV (×1.0), 20mm/mV (×2.0)
Wave sweep speed: 6.25mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s Bandwidth
Diagnostic mode: 0.05Hz~100Hz Monitor mode: 0.5Hz~40Hz Surgery mode: 1Hz~20Hz Strong filter mode: 5Hz~20Hz CMRR>100dB
Notch: 50/60Hz notch filter can be set to on or off
Differential input impedance>5MΩ
Electrode polarization voltage range: ±400mV
Baseline recovery time<3s after defibrillation (in monitor and surgery mode)
Calibration signal:1mV (peak - peak), accuracy ±3%
RESP
Measurement method : Thoracic electrical
bioimpedance Measuring lead: Lead I, II
Wave gain: ×0.25, ×0.5, ×1, ×2
Respiratory impedance range: 0.5-5ΩBaseline
impedance: 500-4000Ω
Gain: 10 grades Scan speed: 6.25mm/s, 12.5 mm/s, 25mm/s
SPO2
Measurement range : 0-100%
Resolution: 1%
Accuracy: ±2%(70-100%, Cat/Dog);
±3%(70-100%);
0-69%,unspecified
Refreshing Rate: 1s
TEMP
Measurement method: Thermistor Measuring range: 5~50°C (41~122°F)
Resolution: 0.1°C
Measurement accuracy: ±0.1°C
Pulse rate
Range: 30~254 bpm
Resolution: 1bpm
Accuracy: ±2bpm (non-motion)
±5bpm (motion)
Refreshing rate: 1s Operation environment
Power: AC 100-250V, 50/60Hz Temperature: 5-40℃ Humidity: <85%
Standard configuratio
SPO2+NIBP+PR+ECG+RESP+Temp
Main unit with SPO2,NIBP,ECG,T1 port
Reusable veterinary cuff(5 sizes)
Animal SPO2 line
Temperature line
ECG line
Stand or wall type for choose