WMV650A Veterinary Patient Monitor

8 inch high resolution display for easy reading

Lightweight,portable design and user-friendly interface for easy operation

Share:

PRODUCT DETAILS

Features

8 inch high resolution display for easy reading

Lightweight,portable design and user-friendly interface for easy operation

Flexible configurations to meet different clinical needs

Built-in rechargeable Lithium-ion battery for fluid

Built-in rechargeable battery

5 hours continuous working

12 months warranty

SPECIFICATIONS

Display

8” color TFT LCD Screen,resolution: 600 x 800

NIBP

Measurement method : Automatic oscillometric method

Operating mode:Manual, automatic, continuous Measurement unit: mmHg/kPa selectable

Typical measurement time: 20~40s Measurement type: Systolic, Diastolic,Mean Measurement range (mmHg)

Range of Systolic pressure: Dog 40-270

Cat 40-200

Others 40-135

Range of Diastolic pressure: Dog 10-210

Cat 10-150

Others 10-95

Range of Mean pressure: Dog 20-230

Cat 20-165

Others 20-105

Measurement accuracy

Maximum average error: ±5mmHg

Maximum standard deviation: 8mmHg

Resolution: 1mmHg

Interval:1,2,3,4,5,10,15,30,60,90,120,180,240,480minutes Overpressure protection: Software and hardware,double

safety protection Cuff pressure range: 0-280mmHg

ECG

Lead type 3-lead:I, II, III

5-lead:I, II, III,aVR, aVL, aVF, V

Display sensitivity: 2.5mm/mV (×0.25), 5mm/mV (×0.5), 10mm/mV (×1.0), 20mm/mV (×2.0)

Wave sweep speed: 6.25mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s Bandwidth

Diagnostic mode: 0.05Hz~100Hz Monitor mode: 0.5Hz~40Hz Surgery mode: 1Hz~20Hz Strong filter mode: 5Hz~20Hz CMRR>100dB

Notch: 50/60Hz notch filter can be set to on or off

Differential input impedance>5MΩ

Electrode polarization voltage range: ±400mV

Baseline recovery time<3s after defibrillation (in monitor and surgery mode)

Calibration signal:1mV (peak - peak), accuracy ±3%

RESP

Measurement method : Thoracic electrical

bioimpedance Measuring lead: Lead I, II

Wave gain: ×0.25, ×0.5, ×1, ×2

Respiratory impedance range: 0.5-5ΩBaseline

impedance: 500-4000Ω

Gain: 10 grades Scan speed: 6.25mm/s, 12.5 mm/s, 25mm/s

SPO2

Measurement range : 0-100%

Resolution: 1%

Accuracy: ±2%(70-100%, Cat/Dog);

±3%(70-100%);

0-69%,unspecified

Refreshing Rate: 1s

TEMP

Measurement method: Thermistor  Measuring range: 5~50°C (41~122°F)

Resolution: 0.1°C

Measurement accuracy: ±0.1°C

Pulse rate

Range: 30~254 bpm

Resolution: 1bpm

Accuracy: ±2bpm (non-motion)

±5bpm (motion)

Refreshing rate: 1s Operation environment

Power: AC 100-250V, 50/60Hz Temperature: 5-40℃ Humidity: <85%

Standard configuratio

SPO2+NIBP+PR+ECG+RESP+Temp

Main unit with SPO2,NIBP,ECG,T1 port

Reusable veterinary cuff(5 sizes)

Animal SPO2 line

Temperature line

ECG line

Stand or wall type for choose